What does a utility buyer check before ordering a transformer?

They check the rating, voltage ratios and vector group against the network, the impedance, and the no-load and load loss figures, because losses are capitalised over decades. Then type test evidence, because a transformer failure takes a substation out.

A utility engineer is evaluating tenders where losses will be capitalised and a failure would be a public event.

Reviewed 4 August 2026

Plact Research

Scope and specifications

Rating and voltage ratio
The core specification.
Vector group and connection
Must match the network configuration.
Impedance
Determines fault current and parallel operation.
No-load and load losses
Capitalised over the asset's life and often decisive in tenders.
Cooling type
Determines rating in service and installation requirements.
Tap changer type and range
On-load or off-circuit changes the equipment substantially.
Insulation level
Must match the system's insulation coordination.

Documents buyers may need

Documents buyers ask a transformer manufacturer for, what each proves, and whether it belongs on the public site
Routine test certificateAsked at: every unit, before dispatchTests performed on the transformer suppliedPer shipment
Type test reportAsked at: tender qualification — frequently mandatoryFull type testing of the design, including short-circuit withstandPublish it
Loss measurement certificateAsked at: acceptance and loss capitalisationMeasured no-load and load losses against the guaranteePer shipment
Temperature rise test reportAsked at: type approvalVerified thermal performance under loadName it, share on request
Oil test reportAsked at: commissioningInsulating oil properties before energisationPer shipment
Manufacturing quality planAsked at: project ordersInspection and hold points during manufactureName it, share on request
Reference list of comparable unitsAsked at: technical evaluationThat units of this rating and design are in servicePublish it

Details for a useful enquiry

Rating, voltage and vector group
The core specification.
Impedance and loss requirements
Frequently specified and guaranteed.
Cooling and installation conditions
Indoor, outdoor and altitude affect design.
Tap changer requirement
Changes the equipment substantially.
Test and inspection requirements
Witness testing needs scheduling.
Delivery location and date
Transport of large units is a project in itself.

Questions suppliers ask

Why do loss figures matter so much in tenders?

Because utilities capitalise losses over the transformer's life, often adding a substantial sum to the evaluated price. A unit with lower losses can win against a cheaper one, so publishing and guaranteeing the figures is competing on the axis that actually decides.

What type testing do buyers expect?

Short-circuit withstand testing is the one most often required and least often held. Publishing which designs have been type tested, by which laboratory and to what standard, is a strong qualification signal and frequently the difference between bidding and not.

How should transport and installation be addressed?

With weights, dimensions and handling requirements published early. Large transformers are transport projects, and buyers need the figures to assess site access. A supplier who provides them upfront avoids the late discovery that a unit cannot reach the substation.

Check which documents and standards your buyer needs; requirements vary by market, customer and contract.